What is pump cavitation? Causes, warning signs and how to prevent it

At a glance: pump cavitation in 60 seconds

What it is
The formation and violent collapse of vapour bubbles at the impeller inlet, when the local pressure of the liquid falls below its vapour pressure.
Root cause
Insufficient suction pressure: the NPSH available (NPSHa) in the installation does not cover the NPSH required (NPSHr) by the pump with an adequate margin.
Warning signs
A gravel-like rattling noise, vibration, falling and fluctuating discharge pressure, loss of flow and mechanical seal leaks.
Cavitation damage
Pitting and material loss on the vanes, damaged mechanical seals, worn bearings and bushes. With corrosive fluids, deterioration speeds up.
Design rule
NPSHa must always exceed NPSHr: as a practical guide, by at least 0.5–1 m, and by more with hot fluids or critical duties.
How to prevent it
Flooded suction, short and generously sized suction pipework, temperature control, a flow rate close to the best efficiency point and the right pump speed.
Safest configuration
Vertical pumps with the casing submerged in the liquid, which eliminate suction lift, or horizontal pumps selected on the real NPSHa of the installation.

The noise is usually the first thing you notice: a constant crackling, as if the pump were moving gravel rather than liquid. Then come the vibration and a fluctuating discharge pressure and, weeks or months later, an impeller with a pitted surface and a mechanical seal that no longer seals. Behind that sequence there is almost always the same phenomenon: pump cavitation, one of the most common — and most avoidable — failure modes of centrifugal pumps.

Cavitation is not a manufacturing defect. It is a problem of the relationship between the pump and its installation: it occurs when the pressure at the impeller inlet drops below the vapour pressure of the liquid. That is why it is solved with data — temperature, tank level, friction losses, NPSH — rather than by blindly replacing the pump.

In this guide we explain what physically happens inside the pump, what cavitation damage to expect, how to tell cavitation apart from the problems it is confused with, how to calculate the NPSH margin and which measures eliminate it, both in existing installations and in new projects. We focus on a particularly demanding case: pumping acids, alkalis and other corrosive fluids with thermoplastic pumps, which is the field in which Tecnium Pumps works.

What pump cavitation is and why it is so destructive

The physics: vapour pressure, bubbles and implosion

Every liquid has a vapour pressure: the pressure below which it starts to boil at a given temperature. Water at 20 °C boils if the absolute pressure drops to around 2.3 kPa; at 80 °C it only needs to drop to around 47 kPa. In other words, the hotter the liquid, the more easily it boils without any heat being added.

In a centrifugal pump, the lowest-pressure point in the whole system is not in the pipework but in the eye of the impeller, right at the leading edge of the vanes. There the liquid accelerates and its static pressure falls. If the local pressure at that point drops below the vapour pressure, the liquid vaporises and small vapour cavities form — hence the name of the phenomenon.

The problem is not how the bubble is born but how it dies. The flow carries the bubbles into areas of the impeller passage where the pressure rises again; there the vapour condenses abruptly and the bubble collapses in microseconds. Each implosion produces a micro-jet of liquid and a pressure wave that strikes the vane surface. Millions of impacts, always concentrated in the same area, are enough to tear material away from any substrate: cast iron, stainless steel or thermoplastic.

It is worth distinguishing true cavitation — vaporisation caused by a lack of pressure — from two phenomena that mimic it: suction recirculation, which appears when the pump runs at flow rates well below its design point, and air or gas entrainment in the suction line. All three damage the pump and make noise, but each is corrected differently, so the diagnosis matters.

Cavitation damage: impeller, mechanical seal and bearings

Cavitation damage is usually visible to the naked eye as soon as the pump is opened. These are the components that suffer most:

  • Impeller. Spongy or rough-looking pitting on the low-pressure side of the vanes, near the leading edge. If the damage appears on the pressure side, close to the impeller eye, the most likely cause is recirculation from running at low flow. On thermoplastic impellers the typical sign is a matt, whitish and rough surface, with a progressive loss of thickness and of the leading-edge profile.

  • Mechanical seal. Vibration and pressure pulsations momentarily separate the seal faces, which can also be left without a liquid film when the liquid vaporises. The result is chipping, heat marks and leaks.

  • Bearings and shaft. Pulsating radial loads deflect the shaft, accelerate bearing wear and punish the coupling.

  • Bushes in sealless pumps. In a magnetic drive pump the bushes are lubricated by the pumped liquid itself. If it vaporises, they run dry and can fail very quickly.

  • Efficiency. An impeller that has lost its geometry delivers less head and uses energy less efficiently: the pump consumes the same or more power to move less liquid.

vertical motorpump

Cavitation rarely destroys a pump overnight: it wears it down progressively. That is why it is detected late, when the bill already includes the impeller, the seal, the bearings and hours of lost production.

Why cavitation is worse with corrosive fluids

In a cold-water pump, cavitation is mainly a problem of noise, erosion and efficiency. When chemicals are being pumped, three aggravating factors come into play:

1Cavitation and chemical attack reinforce each other

In metal pumps, the implosions destroy the passive layer that protects the metal and the fluid attacks the bare metal in every micro-crater, so material is lost far faster than either phenomenon would cause on its own. Thermoplastics do not suffer electrochemical corrosion, but they are subject to mechanical erosion, and a rough, damaged surface is more vulnerable to abrasion by suspended solids.

2Temperature and vapour pressure

Many processes run with hot liquids: pickling baths, degreasing tanks, process solutions. Every extra degree raises the vapour pressure and reduces the margin against cavitation. A system that runs trouble-free at 20 °C can cavitate at 70 °C without anything else having changed.

3Dissolved gases and liquids that release gas

Sodium hypochlorite decomposes, releasing gas, and concentrated hydrochloric acid readily gives off fumes. In the low-pressure zone of the impeller that gas comes out of solution and forms pockets that reduce the pump's capacity and worsen suction problems.

This is why, when pumping aggressive fluids in the chemical industry or in steel and surface treatment, cavitation is not just a hydraulic problem: it is a reliability and safety problem, because it usually ends in a seal failure and a product leak.

Causes and symptoms of cavitation in centrifugal pumps

Insufficient suction pressure: the usual causes in the installation

Almost every cause of cavitation comes down to one thing: the suction pressure reaching the impeller eye is lower than the pump needs. That shortfall can originate in the installation, in the fluid itself or in the way the pump is operated:

CauseWhat happensTypical example
Excessive suction liftThe pump sits above the liquid level and uses up pressure lifting itA surface-mounted pump emptying a pit or a buried tank
Friction losses in the suction lineLong or narrow pipework, bends, dirty strainers or partly closed valves reduce pressure before the flangeA blocked Y-strainer or a bend right at the suction flange
Liquid temperatureVapour pressure rises and the liquid boils soonerRecirculation of hot surface-treatment baths
Low tank levelThe liquid column shrinks and a vortex can formThe final stage of emptying a storage tank
Closed or vacuum tankThe pressure on the liquid surface is below atmosphericSuction from an evaporator or a tank with a blocked vent
Site altitudeLess atmospheric pressure is availableAt 1,000 m above sea level, around 1.2 m less is available than at sea level
Flow above the design pointThe NPSH required by the pump rises with flowA pump running with no back-pressure and an empty discharge line
Very low flowSuction recirculation and heating of the liquidA pump running against an almost closed discharge valve

A very common mistake on site is controlling the flow by throttling the suction valve. The suction valve must always be fully open: flow should be controlled on the discharge side or, better still, with a variable speed drive (VSD).

How to recognise a cavitating pump: noise, vibration and loss of head

The symptoms of cavitation are characteristic but not exclusive. This table helps to separate classic cavitation from the two problems it is most often confused with:

SymptomCavitation from insufficient NPSHLow-flow recirculationAir or gas entrainment
NoiseCrackling, like gravel; increases with flowIrregular knocking at low flowVariable, with gurgling
Discharge pressureDrops and fluctuatesFluctuatesFluctuates; the pump may lose its prime
Damaged area of the impellerLow-pressure side of the vane, near the leading edgePressure side of the vane, near the eyeNo typical pitting
When the discharge is throttled slightlyNoise decreasesNoise increasesLittle change
CorrectionIncrease NPSHa or reduce NPSHrBring the flow closer to the design pointEliminate air ingress and ensure submergence

The definitive check is to measure. A compound gauge on the suction flange allows you to calculate the real NPSH available with the pump running: convert the reading to absolute pressure and metres of liquid column, add the velocity head at the flange and subtract the vapour pressure at the operating temperature. If the result approaches the NPSH required shown on the pump curve for that flow, the diagnosis is clear.

Vibration also provides clues: cavitation produces broadband vibration with no clear dominant frequency, unlike imbalance or misalignment, which show up at specific frequencies linked to the running speed.

NPSH margin: the calculation that separates a healthy pump from a cavitating one

NPSH (Net Positive Suction Head) is the tool for comparing what the installation offers with what the pump needs:

  • NPSH available (NPSHa): what the installation offers. It depends on the tank, the suction pipework and the properties of the fluid. It is calculated by the process engineer.

  • NPSH required (NPSHr): what the pump needs to operate without harmful cavitation. It is given by the manufacturer on the pump curve and increases with flow. It has traditionally been determined as the NPSH at which the pump head drops by 3 % (NPSH3): at that point the pump is already cavitating measurably, hence the need for a margin.

NPSH available is calculated as follows, with all terms in metres of column of the pumped liquid:

NPSHa = (Pa − Pv) / (ρ · g) ± Hz − Hf

Where Pa is the absolute pressure on the liquid surface, Pv the vapour pressure at the operating temperature, ρ the density, Hz the height difference between the liquid surface and the pump centreline (positive with flooded suction, negative with suction lift) and Hf the friction losses in the suction line.

The most underestimated term is vapour pressure, because it rises very quickly with temperature:

Water temperatureVapour pressure (kPa abs.)Equivalent in metres of column
20 °C2.30.24 m
40 °C7.40.76 m
60 °C19.92.07 m
80 °C47.44.97 m
90 °C70.27.41 m

These values are for water; dilute aqueous solutions behave similarly, but with concentrated acids, solvents or mixtures you must use the vapour pressure of the actual product, which can be very different.

Let us look at an example with an open tank at sea level, a pump located 3 m above the minimum liquid level, 1 m of suction losses and a pump with an NPSHr of 3 m at the duty point:

ScenarioNPSHaMarginResult
20 °C, pump 3 m above the liquid level6.1 m+3.1 mCorrect operation
60 °C, same installation4.4 m+1.4 mAcceptable, with little margin if the level drops
80 °C, same installation1.7 m−1.3 mCavitation certain
80 °C, pump 2 m below the liquid level (flooded suction)6.7 m+3.7 mCorrect operation

The same pump, in the same installation, goes from running correctly to cavitating simply because the temperature has changed. And lowering the pump by two metres solves the problem without touching the equipment.

How much margin should you allow? As a practical guide, many projects work with an NPSHa that exceeds NPSHr by at least 0.5–1 m and, in relative terms, by 10–30 % or more. The Hydraulic Institute’s ANSI/HI 9.6.1 guideline recommends margins by type of application, which are stricter for critical duties, hot fluids and pumps with high suction energy. With corrosive fluids, where a seal failure means a leak of aggressive product, it pays to stay at the upper end of those margins.

How to prevent pump cavitation: installation fixes and pump selection

Corrective measures and selection criteria to eliminate cavitation

There are only two ways to gain margin: increase the NPSH available or reduce the NPSH required. This table ranks the most effective measures from least to most effort:

MeasureActs onEffort
Open suction valves fully and clean strainersNPSHa (lower losses)Low
Bring the pump back to a flow close to its best efficiency point (BEP)NPSHrLow
Raise the minimum tank level and adjust the level alarmsNPSHaLow
Increase the suction pipe diameter, remove bends and fit the eccentric reducer flat side upNPSHaMedium
Reduce the running speed with a variable speed driveNPSHrMedium
Cool the liquid or place the pump upstream of the heat exchangerNPSHa (lower vapour pressure)Medium
Install the pump with flooded suction, below the tank levelNPSHaMedium-high
Switch to a vertical pump with a submerged casing or to a model with lower NPSHrBothHigh (project)

When designing the suction pipework, three rules prevent most problems: low velocities (as a guide, below 1.5–2 m/s), a straight run of several pipe diameters before the flange, with no bends or valves right next to the pump, and no high points where pockets of air or gas can collect. Reducing the running speed is also very effective: the NPSH required falls roughly with the square of the speed.

In new projects, the most reliable way to prevent cavitation is to choose a pump configuration that does not depend on suction. The Tecnium Pumps range of plastic pumps offers several answers depending on the installation:

  • BT series vertical sump pumps: the pump casing runs submerged in the liquid, so there is no suction lift to overcome. With no mechanical seal and able to run dry, they are the natural solution for pits, bunds and neutralisation tanks.

  • BV series vertical pumps for external tank mounting: hydrodynamic sealing with no mechanical seal and a design that can run dry when the level fluctuates or the suction empties.

  • BHS series vertical motor pumps: a sealless overflow principle and dry-running capability, for installations with little space.

  • BN process pumps and BV process pumps: horizontal pumps to ISO 2858 / EN 22858, with wide hydraulic coverage that allows you to choose the size whose NPSHr suits the installation, and with variable speed drives and priming tanks available as accessories.

  • BKM series magnetic drive pumps: zero leakage for toxic or volatile products. They are the least tolerant of liquid vaporisation, so they need a properly verified NPSH; electronic dry-running protection is available.

  • BH series close-coupled pumps and BX series motor pumps: compact units with dry-running protection and self-priming options.

The material also matters, because it determines the operating temperature and therefore the vapour pressure. According to Tecnium’s technical data, PP retains its mechanical stability up to 90 °C, PE up to 80 °C, PVDF up to 120 °C and E-CTFE up to 150 °C in continuous service. The closer you operate to those limits, the more important it is to verify the NPSH margin.

 Pump cavitation: frequently asked questions

What is pump cavitation?

It is the formation of vapour bubbles at the impeller inlet when the pressure of the liquid falls below its vapour pressure, followed by the violent collapse of those bubbles in areas of higher pressure. That collapse erodes the impeller, causes vibration and reduces the pump's head and flow.

How do I know if my pump is cavitating?

Typical symptoms are a gravel-like crackling noise, vibration, unstable discharge pressure and loss of flow. Confirmation comes from measuring the pressure at the suction flange and calculating the real NPSH available: if it is below or very close to the NPSH required on the curve, the pump is cavitating.

What is the difference between NPSH available and NPSH required?

NPSH available is the net pressure that the installation delivers at the suction and depends on the tank, the pipework and the fluid. NPSH required is the minimum the pump needs to avoid cavitation and is given by the manufacturer on the pump curve. To prevent cavitation, the available value must always exceed the required value.

How much NPSH margin should I allow?

As a practical guide, an NPSH available at least 0.5–1 m above the NPSH required and, in relative terms, 10–30 % higher or more. With hot, volatile or corrosive fluids, and on critical duties, it is advisable to work with larger margins, as recommended by the ANSI/HI 9.6.1 guideline.

Can a plastic pump suffer cavitation damage?

Yes. No material is immune to cavitation. Thermoplastics do not suffer the electrochemical corrosion that makes cavitation worse in metals, but mechanical erosion does wear them. The solution is not to change material but to guarantee a sufficient NPSH margin and to choose the right material for the actual operating temperature.

How do you prevent cavitation when pumping from a pit or a buried tank?

The most reliable option is not to rely on suction at all: install a vertical sump pump whose casing runs submerged in the liquid, such as the BT series, which eliminates suction lift and can run dry. If a horizontal pump is kept at surface level, suction lift and suction losses must be kept to a minimum and the NPSH checked at the lowest expected level.

Do you suspect one of your pumps is cavitating, or are you specifying a new installation? Send our technical team the fluid and its concentration, the maximum temperature, the required flow and head, the minimum liquid level relative to the pump and a sketch of the suction line. With that information we will check the NPSH margin and propose the right configuration. Request your free quote.